BVKNJ - W/B EPOXY CURING PRIMER SOLUTION, ECW-104
- MSDS: BVKNJ
- Manufacturer: DEXTER CROWN METRO AERO CTGS
- Product Name: W/B EPOXY CURING PRIMER SOLUTION, ECW-104
- National Stock Number: 8010-00N051036
Product Identification
Product ID:W/B EPOXY CURING PRIMER SOLUTION, ECW-104
MSDS Date:07/19/1993
FSC:8010
NIIN:00N051036
MSDS Number: BVKNJ
Responsible Party
GREENVILLE, SC 29606
US
Emergency Phone: 803-277-1870
Info Phone: 803-277-1870
Cage: 0S4B8
Contractor
Telephone: 803-277-1870
Cage: 0S4B8
Ingredients
NO INGREDIENT FOR THIS FORMULATION_INGREDIENT
Hazards
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:NO Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE: OVEREXP BY INHAL MAY CAUSE
IRRIT OF RESP TRACT, HDCH, DIZZ/DROW. SKIN/EYE: IRRITANT TO EYES
AND SKIN. CHRONIC: THOSE HAZ MATLS MAY EFT FOLLOWING ORGANS:
KIDNEYS, RESP TRACT, BLOOD, LIVER, CNS.
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:SEE HEALTH HAZARDS.
Medical Cond Aggravated by Exposure:UNKNOWN @ THIS TIME.
First Aid
First Aid:INHAL: REMOVE FROM EXPOS. EYE: FLUSH IMMED WITH LARGE AMOUNTS
OF RUNNING WATER FOR AT LEAST 15 MINUTES. SKIN: REMOVE CONTAMD
CLTHG AND WASH SKIN W/SOAP AND WATER. INGEST: DRINK WATER. IF NEC,
CONSULT A PHYS FOR ANY OF THESE CNDTNS.
Fire Fighting
Flash Point Method:SCC
Flash Point:180F,82C
Lower Limits:1.26%
Extinguishing Media:USE WATER FOG, FOAM, DRY CHEMICAL, OR CARBON
DIOXIDE.
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED SCBA AND FULL
PROTECTIVE EQUIPMENT .
Unusual Fire/Explosion Hazard:NONE SPECIFIED BY MANUFACTURER.
Accidental Release
Spill Release Procedures:AVOID BRTHG VAPS, VENT AREA, AND REMOVE WITH
INERT ABSORBANT AND NON-SPARKING TOOLS.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
Handling
Handling and Storage Precautions:DO NOT TAKE INTERNALLY. MAKE SURE DRUM
IS COMPLETEY EMPTY BEFORE ATTEMTPING TO WELD/BRAZE. DRUM SHOULD BE
INDUSTRIALLY CLEANED PRIOR TO USE.
Other Precautions:DO NOT FLAME CUT, BRAZE/WELD W/OUT A NIOSH/MSHA
APPRVD RESP/APPROP VENT.
Exposure Controls
Respiratory Protection:WHERE GEN DILUT/LOC EXHST FAILS TO ADEQUATELY
DILUTE TWA/PEL OF MATL, THEN RESP PROT SHOULD BE USED AS FOLLOWS:
I/A/W 29CFR1910.134, USE NIOSH/MSHA APPRVD AIR LINE TYPE RESP/HOODS
FOR ENCLSD AND CONF INED AREAS. NIOSH/MSHA APPRVD (SUPDAT)
Ventilation:PROVIDE GEN DILUT/LOC EXHST VENT TO KEEP TWA AND LEL BELOW
ACCEPTABLE LIM & TO REMOVE DECOMP PROD.
Protective Gloves:CHEMICALLY RESISTANT GLOVES.
Eye Protection:ANSI APPRVD CHEM WORK GOGGS .
Other Protective Equipment:NONE SPECIFIED BY MANUFACTURER.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
RESP PROT: AIR PURIFYING RESP MAY BE USED FOR OTHER AREAS.
Chemical Properties
Boiling Pt:B.P. Text:>207F,>97C
Vapor Pres:SEE INGRED
Vapor Density:HVR/AIR
Spec Gravity:0.95
Appearance and Odor:NONE SPECIFIED BY MANUFACTURER.
Stability
Stability Indicator/Materials to Avoid:YES
NONE SPECIFIED BY MANUFACTURER.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:FUMES MAY CNTN CARBON MONOXIDE AND
OXIDES OF NITROGEN. MAY PRODUCE HAZ FUMES WHEN HEATED TO DECOMP AS
IN WELDING.
Disposal
Waste Disposal Methods:DISPOSE OF I/A/W LOCAL, STATE, AND FEDERAL
REGULATIONS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.